Fluidguard Machinery Equipment Co., Ltd. amy@aida-machinery.com
Call Us : 0086-15137376132
Model : E0620X1
Type : Coalescing Filters
Replacement for : E0620X1
Installed inside Walker A‑series filter housing, removes 1μm solid particles and liquid oil‑water droplets from compressed‑air, as intermediate‑stage filtration for post‑treatment system.
Part numbers marked "replacement" are not affiliated with the original manufacture.
Main Features
Type:X‑grade coalescing filter element;Filter media:borosilicate glass‑fiber;bayonet quick‑install end‑cap
Rated flow:620Nm³/h;Max working pressure:16bar;Working temperature:1.5‑66℃
Filtration precision:1μm;Residual oil content ≤0.6mg/m³
Function:filter solid particles, separate liquid oil mist and bulk water droplets in compressed‑air
Common faults:differential pressure rapid rise, filter‑element saturation, end‑cap seal leakage, oil‑mist penetration
Applications
Maintenance suggestion: replace element when ΔP>0.07MPa; inspect bayonet sealing rings for air‑leakage; cannot exceed rated flow and pressure; recommended service cycle 8000 working‑hours。