Fluidguard Machinery Equipment Co., Ltd. amy@aida-machinery.com
Call Us : 0086-15137376132
Model : E120HE
Type : Air Filters
Replacement for : E120HE
Installed inside filter housing, remove sub‑micron oil mist, fine solid particles from compressed‑air, obtain clean compressed‑air for downstream equipment.
Part numbers marked "replacement" are not affiliated with the original manufacture.
Main Features
Part number:E120HE;Matching housing:Parker E120 series filter housing;Related grades:E120‑GP、E120‑AC
Type:high‑efficiency coalescing filter element;Filter media:borosilicate glass fiber;Inner‑outer metal support cage
Rated flow:120Nm³/min;Max working pressure:16bar;Working temperature:1.5‑66℃
Function:remove 0.01μm solid particles, residual oil mist;residual oil content ≤0.01ppm
Common faults:differential pressure rising quickly, filter element saturated, oil‑mist passing‑through, end‑cover seal leakage
Applications
Maintenance suggestion: replace element when pressure difference>0.5bar; check end‑cover O‑ring for air leakage; strictly follow flow rate requirement; cannot exceed rated pressure.